・ When installing a low-voltage light fixture for use on a dry wooden floor or similar insulated material.・ When the light fixture features a double insulation structure in compliance with the Electrical If the seal adhesion is not good, water may enter.If the mounting surface is irregular, water may enter through recessed sections.In case of screw-type terminalDo not connect cables with different diameters.PuttyRubber packingMake the cut part of the rubber packing smaller than the diameter of the power cable routing hole.Water drain holeCorrect connectionIncorrect connectionInsufficient insertion10 cm or moreHeat dissipation hole10 cm or more10 cm or moreCeiling materialStructural material20 cm or moreHeat insulation material・ Do not apply tensile force to the connecting point or the lead wire inside the light fixture. If tensile force is applied to the terminal, damage can occur.・ When use of waterproof gland and cable type are specified, such as in the case of an underground light fixture or submersible light fixture, be sure to use the specified cable and waterproof packing.・ When using an EM(Eco Material) cable with a polyethylene insulation coating, cover the exposed insulation section near the terminal with tape for protection.・ When connecting cables in a humid place or place where water is used, ensure thorough insulation treatment. ・ About the grounding work for equipment inverter devices and emergency exit lights・ When storing the light fixture, place it above the floor in a well-ventilated place, such as on a wooden shelf.・ In the case of the emergency light or emergency exit light with a integrated battery, correct resistance value cannot be obtained while the battery is connected. Be sure to disconnect the battery connector before measuring the insulation resistance.Water drain holeGrounding workClass D grounding workClass C grounding workClass A grounding work2 MΩ or more30 MΩ or moreVoltage to ground of 150 V or lessOtherWaterproof packingPower supply cableGland capMain glandCover with insulation tapeBe sure to observe0.1 MΩ or more0.2 MΩ or more0.4 MΩ or more357・ When using power supply units side by side, please leave a ・ After the light fixture is used for three years or more, inspect the external wiring once a year to ensure safety. If the cables are damaged or abnormal, replace them.Indoor Wiring Regulations 3210-5・ In the case of the rainproof light fixture with a water drain hole, install the light fixture in such a way that the water drain hole is located at the bottom.・ Do not install floodlights or underground light fixtures in any of the following places. Failure to observe this ・ It is prohibited to install light fixtures above or near heating equipment, flames, etc. Excessive heat can cause shortening of lamp life, fire, deformation or falling of light fixtures.・ In the case of quick-connection terminals, remove the cable sheath as per the specified length, and insert Notice for installationFailure to observe the instructions can cause a fire, falling of the fixture overheating/deformation of the light fixture, insulation failure or electrical leakage.・ The light fixtures can be installed only in the direction shown in the photos on the product pages (unless otherwise specified).・ Be sure to install the light fixture and lamps in the specified direction. Installation of the light fixture/lamps in a direction other than specified can cause overheating, deformation, insulation failure and falling of the light globe. It also results in a contact failure at the socket of the LED module/unit, and causes lighting failure.・ Make sure that the light fixture is not too close to the ceiling surface. If the light fixture is installed too close to the ceiling surface, the light globe may not be able to be removed, thus disallowing replacement of the lamp. In addition, convection of heated air can cause a dark stain on the ceiling surface.・ Make sure that the mounting surface is strong enough to hold the light fixture. If the strength of the mounting surface is not strong enough or if the light fixture is installed in a method other than specified, the light fixture may fall and the ceiling/wall surface may become bent or damaged. Reinforce the mounting surface or install the light fixture at a location with reinforcement. [Note 3] If the light fixture is installed to a soft ceiling such as a rockwool ceiling, the ceiling material may become damaged, and a gap may be created between the frame and ceiling surface.・ Do not embed the light fixture for general outdoor use into the ceiling.Select the light fixture suitable for the place of use. Never attampt to modify the light fixture.When connecting the power cable to the power supply terminals of the light fixture, ensure firm and secure connection. Loose connection can lead to a fire or electric shock. [Note 4]・ In the case of screw-type terminals, tighten the screws tightly. Remove the cable sheath in the length indicated on the parts.In the case of feed wiring, connect cables of the same wire diameter to the screw-type terminals.If the wire diameters differ, connection failure can occur in the thinner wire and cause excessive heating.space of 10 cm or more between them.[Note 3]Indoor Wiring Regulations 3205-3: When installing a light fixture, reinforce the structural material or use a wooden reinforcement or outlet box in order to ensure that the mounting surface is strong enough to support the weight of the light fixture.* Do not mount the light fixture directly to a resin outlet box.・ Do not install the light fixture in a place where the heat resistance of interior material is only up to 90°C or lower, such as vinyl wallpaper. Otherwise, the wallpaper can become scorched and discolors.・ If the light fixture is installed to a ceiling or wall immediately after the pasting of wallpaper, adhesive can damage the plated or coated surface of the light fixture. Install the light fixture after the adhesive dries sufficiently.・ When installing the light fixture directly to a concrete surface, install the light fixture after the concrete dries sufficiently. (Be sure to take the construction schedule into consideration). If the concrete is not dry, the light fixture can absorb moisture from the concrete, and the insulation can deteriorate. In addition, alkali components in the absorbed moisture can damage the coating of the light fixture and cause it to peel off.・ In the case of the moisture-proof or rainproof light fixture, make sure that the rubber packing firmly contacts the mounting surfaces of the wall and light fixture. If the mounting surface is irregular(such as a tiled surface), be sure to fill the gap around the mounting section of the light fixture with a caulking agent. Also, ensure that water will not enter the power cable routing hole in the light fixture.* For the installation of light fixtures for outdoor use, it is recommended to use rust-resistant wood screws such as stainless steel screws.caution can result in a fire, electrical leakage or shortening of the service life of lamps. 1. Place where dead leaves and branches can fall and collect on or around the front glass of the light 2. Place where the front glass of the light fixture will be covered with grass or tree leaves 3. Place where the light fixture will become submerged in water when it rains 4. Poorly drained place 5. Place where people or cars pass by frequentlyeach cable straight all the way.Compatible cables are 1.6-/2.0-mm-diameter single-core copper wires.fixtureFor example, when 20 light fixtures with insulation resistance of 100 Mohms are connected to one circuit, the insulation resistance of the circuit will be 5 Mohms.[Note 4]* For the connection of electric wires to an electric machine or appliance (incandescent lamp, discharge lamp, etc.), robust and complete electrical connection must be ensured by using a screw-fastening method or method with an equivalent effect and there shall be no tension applied to the connecting point. (Summary of Article 167 of Interpretation of Technical Standards for Electrical Equipment)* If the terminal is structured for connection of only one cable, do not connect two or more cables. (Summary of Internal Wiring Regulations 3102-6)* When connecting a cable to a press-screw-type terminal, insert the wire securely to the specified position. (Summary of Internal Wiring Regulations 3102-6)* Observe Article 198 of Interpretation of Technical Standard for Electrical Equipment when connecting wires inside a show window or showcase.It is recommended to use self-bonding tape.1. Place with high humidity and with moisture such as bathroom or outdoors.2. When the light fixture requires a working voltage of 150 V or more. (Note that grounding work is not conducted in some cases. Refer to Articles 29 and 206 of Interpretation of Technical Standards for Electrical Equipment) [Note 5][Note 5]Classification of machinery and applianceLow voltage of 300 V or lessLow voltage of higher than 300 VHigh voltage or extra-high voltage When any of the following applies or when permission is obtained from the head of the regional Bureau of Economy, Trade and Industry for special reasons, the above regulations do not apply.・ When installing a light fixture with working voltage of 300-V DC or AC voltage to ground of 150 V or less in a dry place.Appliances and Materials Safety Act (former Electrical Appliance and Material Control Law).Inverters and emergency exit lights are provided with a grounding terminal as specified by JIS, Electrical Appliances and Materials Safety Act and other regulations. Conduct Class D grounding work in compliance with Articles 29 and 206 of Interpretation of Technical Standards for Electrical Equipment and also in consideration of safety and noise reduction.[Note 6]JIS and Technical Standards for Electrical Equipment stipulate the following insulation resistance value per light fixture.Light fixture JISC 8106HotColdHot : Insulation resistance measured immediately after the temperature stabilizes following the lighting of the lampCold : Insulation resistance with the light OFFElectric circuit Article 58 of Technical Standards for Electrical EquipmentWorking voltage of 300 V or lessWorking voltage of higher than 300 VConnect the grounding cable in accordance with regulations(Technical Standard for Electrical Equipment).* It is also recommended to install an electrical leakage circuit breaker as needed.・ Example of installation cases requiring grounding workMeasure and confirm the insulation resistance after the installation of the light fixture. [Note 6]If the insulation resistance is lower than the specified value, electric hazards (electric shock, fire) may occur. Repair the insulation before supplying electricity to the light fixture.・ When the power supply voltage is 100 V, the insulation resistance of the circuit must be 0.1 Mohms or higher.・ If the light fixture is installed on a still-wet concrete ceiling in a newly constructed building/house, degradation of the insulation may occur.Install the light fixture after the concrete dries sufficiently or operate the air conditioner before turning on the light. If the degradation of the insulation is only slight, the insulation will recover after supplying electricity for about one day. If the light fixture is left in a humid place for an extended period of time, degradation of the insulation will occur.
元のページ ../index.html#357